Design process

From idea to prototype: the simulation process in TracePro, OSLO and OptiSystem step by step

Optical simulation is not a single step but a sequence of decisions: from requirements, through the concept and the device model, to the prototype and measurement. Each stage answers a different question and uses a different tool. Below we walk through this process step by step, so that it is clear when to use TracePro, when OSLO and when OptiSystem.

From idea to prototype: the simulation process in TracePro, OSLO and OptiSystem step by step
Request a quote Start a trial

A good design process answers two questions: what do we want to achieve, and how will we know we have succeeded. Only then are the tools chosen. This article shows a typical path from idea to prototype and the points at which OSLO, TracePro and OptiSystem come in.

We describe how to choose tools in general in the article How to choose optical simulation software.

Step 1: requirements

Everything starts with the requirements. What is the device supposed to do? What image, light distribution or signal should it deliver? Under what conditions, at what size and with what tolerance?

At this point it is also worth writing down the acceptance criterion, that is the number whose achievement we will consider a success: an MTF value, a stray light level, a BER, illumination uniformity. Without it, every simulation only shows that something is happening, not whether it is good enough.

Step 2: concept in OSLO

For lens and mirror systems, the first decision is the choice of optical layout. OSLO lets you design it and optimize it against the chosen criteria, as well as check aberrations across the whole field. We describe the basics in the article Optimization of optical systems.

This stage produces a nominal design that works under ideal conditions. The next steps check whether it will also work in reality.

Step 3: tolerances

A system that works in the nominal model may fail once manufactured. Tolerance analysis in OSLO shows how deviations in radii of curvature, thicknesses, decentration or tilt will affect image quality, and which of them are critical. Details are in the article Tolerance analysis of optical systems in OSLO.

The result goes into the production specification: critical parameters require tight tolerances, while the rest can be relaxed to reduce cost.

Step 4: the device model in TracePro

The optical system is not the whole device. Mounts, housing, coatings, the light source and the detector all affect the result. The model from OSLO can be transferred to TracePro, which accepts the LEN file format, and the remaining elements added. TracePro uses non-sequential Monte Carlo ray tracing, so it shows where light ends up even outside the ideal path.

At this stage you check intensity distributions, efficiency and, above all, stray light. Early checking of ray paths in the CAD environment is possible with RayViz, as we describe in the article Visualizing optical simulation results in RayViz.

Step 5: stray light and coatings

Reflections and scattering are among the most common reasons why a finished device performs worse than the model. TracePro lets you identify unwanted light paths and evaluate the contribution of individual surfaces. We describe the effect of coatings on reflections in the article Thin-film coating design, and the phenomenon itself in the article Stray light analysis: what it is.

Step 6: system analysis in OptiSystem

If the device is part of a communication link, for example a transceiver in a fiber-optic link, a system-level analysis is also needed. OptiSystem simulates the entire link from transmitter to receiver and lets you evaluate BER, OSNR and Q-factor as a function of the link parameters. We write about how this is done in the article Simulation of broadband fiber-optic networks.

This step is not needed when only imaging or illumination optics are being designed.

Step 7: prototype and measurement

The prototype is a test of the model. You measure the same things the simulation predicted: light distribution, image quality, BER. When the measurements and the model differ, the difference is information: it points to an assumption that needs to be corrected.

Measurements can be automated, as we describe in the article Automating photonic measurements: OptiInstrument.

Step 8: correlation and the next iteration

Once the measurement results have been fed into the model, it can be used to check further variants without building hardware each time. This is where simulation pays for itself: the better correlated the model, the fewer prototypes are needed. We write about the economics of this approach in the article How to reduce R&D costs with simulation.

Example workflow in brief

1. Define the requirements and acceptance criterion

Write down what is to be achieved and how you will measure it.

2. Design the system in OSLO

Choose and optimize the optical layout.

3. Check the tolerances

Identify the critical parameters.

4. Build the device model in TracePro

Add the mounts, housing, coatings, source and detector.

5. Analyze stray light

Identify unwanted paths and improve the design.

6. Add system analysis if needed

Use OptiSystem for devices operating in communication links.

7. Build the prototype and measure

Compare the results with the model.

8. Correct the model and repeat

Use the model for further variants.

Which tool for which stage

Stage Tool
Design and optimization of the system OSLO
Tolerance analysis OSLO
Early verification in CAD RayViz
Device model and stray light TracePro
System-level link analysis OptiSystem
Automating prototype measurements OptiInstrument

The most common mistakes in the simulation process

Choosing software before defining the problem

The tool is chosen to fit the question we want to answer, not the other way round.

No acceptance criterion

Without a defined number, it is hard to judge whether the result is good enough.

Ignoring tolerances

The nominal system is only half the answer.

A model without mechanics

Mounts and housing are part of the optical path if they can reflect or scatter light.

No correlation with measurement

A model that has never been compared with reality is a hypothesis, not a tool.

Summary

The simulation process is a sequence of stages, each answering a different question. OSLO helps design the system and check tolerances, TracePro brings it into a device model and reveals stray light, and OptiSystem lets you evaluate performance in a communication link. The prototype and measurement close the loop, and after correlation the model becomes a tool for further work.

The most important thing is to start with the requirements and the acceptance criterion, and to choose the tools to fit the problem. In many projects one or two programs are enough.

Manufacturer resources

OSLO and TracePro working together: Lambda Research: Optical System Design with TracePro and OSLO

Workflow from OSLO to TracePro: Lambda Research: Integrating TracePro and OSLO for Comprehensive Optical System Design

OptiSystem product page: Optiwave: OptiSystem

Frequently asked questions
From idea to prototype: the simulation process in TracePro, OSLO and OptiSystem step by step

Where should an optical design project start?

With the requirements, not with the software. You need to define what the device is to do, under what conditions and with what tolerance, and which parameters will be the acceptance criterion. Only then can the simulation method be chosen.

When should OSLO be used and when TracePro?

OSLO is used to design and optimize the optical system and to analyze aberrations and tolerances. TracePro analyzes the entire device in 3D together with the mounts, coatings, light source and stray light. They are usually used one after the other.

What is OptiSystem used for in this process?

OptiSystem is used for system-level simulation of links and transmission systems, for example BER, OSNR and Q-factor. It is needed when the device is part of a communication link, not when only imaging or illumination optics are being designed.

Why do a tolerance analysis before the prototype?

It shows which parameters are critical and how fabrication and assembly deviations will affect performance. This way the prototype is built with knowledge of what needs to be controlled.

How often should the model be compared with measurement?

After every prototype. Correlating the model with measurement lets you correct the assumptions and then use the model for further variants without building hardware each time.

Do all three programs have to be used in every project?

No. They are chosen to fit the problem: a lens design usually starts with OSLO, a device with mechanics and stray light requires TracePro, and a telecommunication link requires OptiSystem. In many projects one or two programs are enough.

Ready to check it on your own project?

Ask our engineers for a tailored quote or start a free trial today.

Request a quote Start a trial

← All articles